Breather - 3DU (Remove and Replace)
Correction code
3901020102
FRT
0.12
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Front drive unit breather |
![]() 5 Nm (3.7 lbs-ft) |
|
Replace |
Remove
- Remove the HEPA filter assembly. See HEPA Filter Assembly (Remove and Replace).
-
Move the front harness bracket forward appropriately to remove the front
drive unit breather.
TipUse of the following tool(s) is recommended:
- Ratchet/torque wrench
- ¼ in to 3/8 in adapter
- 22 mm socket
- 3 in extension
Install
-
Install the new front drive unit
breather.
5 Nm (3.7 lbs-ft)TipUse of the following tool(s) is recommended:- Ratchet/torque wrench
- ¼ in to 3/8 in adapter
- 22 mm socket
- 3 in extension
- Install the HEPA filter assembly. See HEPA Filter Assembly (Remove and Replace).