Air Vent - B-Pillar - Upper - LH (Model YL) (Remove and Replace)
Correction code
15180101302
FRT
0.30
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Screws (x4) that attach the air duct to the LH B-pillar upper trim assembly |
![]() 1.3 Nm (1.0 lbs-ft) |
|
Reuse |
Remove
- Remove the LH B-pillar air duct. See Air Duct - B-Pillar - Upper - LH (Model YL) (Remove and Replace).
-
Remove the screws (x3) that attach the
air vent to the LH B-pillar trim assembly.
TipUse of the following tool(s) is recommended:
- Torx T20 socket
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
-
Release the locator clips (x6) that
attach the air vent to the LH B-pillar trim assembly, and then remove the air vent from
the trim assembly.
Install
-
Install the locator clips (x6) that
attach the air vent to the LH B-pillar trim.
NoteMake sure that all clips are fully engaged.
-
Install the screws (x3) that attach
the air vent to the LH B-pillar trim.
1.3 Nm (1.0 lbs-ft)TipUse of the following tool(s) is recommended:- Torx T20 socket
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
- Install the LH B-pillar air duct. See Air Duct - B-Pillar - Upper - LH (Model YL) (Remove and Replace).