LV Power (Disconnect and Connect) (Modify)
Correction code
17010410
FRT
0.12
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate
Times to learn more about FRTs and how
they are created. To provide feedback on FRT values, email ServiceManualFeedback@tesla.com.
NOTE: See Personal Protection
to make sure wearing proper PPE when performing the below procedure.
NOTE: See Ergonomic Precautions for safe and
healthy working practices.
- 2025-10-30: Added a caution to make sure windows are not moved for at least 1 minute before disconnecting the 12V/LV power.
- 2025-10-16: Updated steps to connect/disconnect LV battery connector.
- 2025-03-26: Updated HEPA filter reference.
Disconnect
- Remove the HEPA filter or cowl assembly. See HEPA Filter Assembly (Remove and Replace) or Cowl Assembly - non-HEPA (Model Y Standard) (Remove and Install).
-
Power off the vehicle from
the center display.
NoteOn the touchscreen, touch .
-
Disconnect the LV battery connector from the LV battery.
-
Disconnect the first
responder loop.
NoteBefore proceeding to service the vehicle, allow 2 minutes for all electrical circuits to discharge.
- If LV power was disconnected to service a high voltage component, verify that high voltage power is no longer available to that component. See Vehicle HV Disablement Procedure.
Connect
-
Connect the first responder
loop.
CAUTIONConnect the first responder loop BEFORE connecting the LV battery connector.
-
Connect the LV battery connector to the LV battery.
- Install the HEPA filter or cowl assembly. See HEPA Filter Assembly (Remove and Replace) or Cowl Assembly - non-HEPA (Model Y Standard) (Remove and Install).
- Raise the LH front window and close the LH front door.