LV Power (Disconnect and Connect)
Correction code
170104000.1
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are
created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com.
NOTE: See Personal Protection to make
sure wearing proper PPE when performing the below procedure.
- 2025-03-26: Updated HEPA filter reference.
Disconnect
- Remove the HEPA filter assembly. See HEPA FILTER (Remove and Replace).
-
Power off the vehicle from
the center display.
NoteOn the touchscreen, touch.
- Disconnect the LV battery connector from the LV battery: release the green locking tab, press the black connector (if applicable, on 16V battery), pull the black connector lock outwards to release the connector, and then pull up to disconnect the connector.
-
Disconnect the first
responder loop.
NoteBefore proceeding to service the vehicle, allow 2 minutes for all electrical circuits to discharge.
- If LV power was disconnected to service a high voltage component, verify that high voltage power is no longer available to that component. See Vehicle HV Disablement Procedure.
Connect
-
Connect the first responder
loop.
CAUTIONConnect the first responder loop BEFORE connecting the LV battery connector.
- Connect the LV battery connectors to the LV battery: insert the connector, push the black connector lock inwards to engage the lock, ensure the connector is fully seated, and then engage the green locking tab.
- Install the HEPA filter assembly. See HEPA FILTER (Remove and Replace).
- Raise the LH front window and close the LH front door.