USB Panel - Center Console (Model Y Standard) (Remove and Install)
Correction code
15190405201
FRT
0.12
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and FRT
listed above reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times
to learn more about FRTs and how they are created.
NOTE: See Personal Protection
to make sure you are wearing proper PPE when performing the procedure
below.
NOTE:
See Ergonomic Precautions for
safe and healthy working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Screws (x3) that attach the inductive charger module to the phone dock |
![]() 1.2 Nm (.9 lbs-ft) |
|
Reuse |
Remove
- Remove the phone dock assembly from the center console. See USB Controller (VCUSB) - Center Console (Model Y Standard) (Remove and Install).
-
Remove the inductive charger module
from the phone dock.
Install
-
Install the inductive charger module to the phone dock.
- Install the phone dock assembly to the center console. See USB Controller (VCUSB) - Center Console (Model Y Standard) (Remove and Install).