HVAC- UPPER AND LOWER ACTUATOR - MODEL Y. (Remove and Install)
Correction code
1810011401
FRT
0.20
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are
created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com.
NOTE: See Personal Protection to make
sure wearing proper PPE when performing the below procedure.
Torque Specifications
Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
---|---|---|---|---|
Screws (x2) that secure the upper mode actuator |
![]() 1.25 Nm (.9 lbs-ft) |
|
Reuse |
Remove
- Remove the RH instrument panel air wave duct. See INSTRUMENT PANEL - AIR WAVE DUCT - RIGHT HAND (Remove and Install).
-
Remove the screws (x2) that secure the upper mode actuator, disconnect the connector,
and then remove the actuator.
TIpUse of the following tool(s) is recommended:
- 6 mm socket
- 4 in extension
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
Install
-
Insert the upper mode actuator into the keyway, connect the actuator connector, and
then install the screws (x2) that secure the actuator.1.25 Nm (.9 lbs-ft)TIpUse of the following tool(s) is recommended:
- 6 mm socket
- 4 in extension
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
- Install the RH instrument panel air wave duct. See INSTRUMENT PANEL - AIR WAVE DUCT - RIGHT HAND (Remove and Install).