HVAC- Actuator - Upper (Remove and Install)
Correction code
1810011401
FRT
0.30
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Screws (x2) that secure the upper mode actuator |
![]() 1.25 Nm (.9 lbs-ft) |
|
Reuse |
Remove
- Remove the RH instrument panel air wave duct. See Instrument Panel - Air Wave Duct - RH (Remove and Install).
-
Remove the screws (x2) that secure the upper mode actuator, disconnect the connector,
and then remove the actuator.
TipUse of the following tool(s) is recommended:
- 6 mm socket
- 4 in extension
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
Install
-
Insert the upper mode actuator into the keyway, connect the actuator connector, and
then install the screws (x2) that secure the actuator.
1.25 Nm (.9 lbs-ft)TipUse of the following tool(s) is recommended:- 6 mm socket
- 4 in extension
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
- Install the RH instrument panel air wave duct. See Instrument Panel - Air Wave Duct - RH (Remove and Install).