Carbon Filter (Remove and Replace)
Correction code
1810010202
FRT
0.18
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and FRT
listed above reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times
to learn more about FRTs and how they are created.
NOTE: See Personal Protection
to make sure you are wearing proper PPE when performing the procedure
below.
NOTE:
See Ergonomic Precautions for
safe and healthy working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Screws (x10) that secure the HEPA filter assembly cover |
![]() 2.4 Nm (1.8 lbs-ft) |
|
Reuse |
Remove
- Remove the HEPA filter assembly. See HEPA Filter Assembly (Remove and Replace).
-
Remove the screws (x10) that secure the HEPA filter assembly cover.
TIpUse of the following tool(s) is recommended:
- Torx T20 socket
- Cordless Ratchet/Impact Driver
- Wiha Torque Screwdriver 0.8-5 Nm screwdriver (installation only)
-
Remove the carbon filters.
Install
-
Install the carbon filters.
NotePay attention to the installation direction.
-
Install the screws (x10) that secure
the HEPA filter assembly cover.
2.4 Nm (1.8 lbs-ft)TIpUse of the following tool(s) is recommended:- Torx T20 socket
- Cordless Ratchet/Impact Driver
- Wiha Torque Screwdriver 0.8-5 Nm screwdriver (installation only)
- Install the HEPA filter assembly. See HEPA Filter Assembly (Remove and Replace).