Busbar - Fast Charge Contactor To Direct Current Busbar - Positive (Model YL) (Remove and Replace)
Correction code
16300500702
FRT
2.04
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Patch bolt that attaches the direct current link busbar to the fast charge contactor |
![]() 10 Nm (7.4 lbs-ft) - 180 degrees |
|
Replace | 1104475-00-F Note Tighten the bolt to 10 Nm, back off 180 degrees, then torque to 10 Nm. |
Remove
-
Remove the fast charge access insulator. See Insulator - Fast Charge Access - Ancillary Bay (Model YL) (Remove and Replace).
NoteDuring removal, certain steps require extra care. See the animation(s) for detailed guidance.
-
Release the location pins (x2), then remove and discard the patch bolt that attaches
the direct current link positive busbar to the fast charge contactor.
TipUse of the following tool(s) is recommended:
- SKT, 1/4" SQ DR, 13MM, HV INSULATED
Replace
-
Secure the location pins (x2) and install a new patch bolt that attaches the direct
current link positive busbar to the fast charge contactor.
10 Nm (7.4 lbs-ft) - 180 degreesNoteTighten the bolt to 10 Nm, back off 180 degrees, then torque to 10 Nm.NoteMark the bolt after torque.TipUse of the following tool(s) is recommended:- SKT, 1/4" SQ DR, 13MM, HV INSULATED
- Install the fast charge access insulator. See Insulator - Fast Charge Access - Ancillary Bay (Model YL) (Remove and Replace).