Hose - Rear Drive Inverter Outlet - 3DU (Remove and Install)
Correction code
NEW
FRT 0.6
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are
created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com.
NOTE: See Personal Protection to make
sure wearing proper PPE when performing the below procedure.
- 1080568-00-A Fluid Catcher
- 1135762-00-A Kit, Svc Plug, Cooling Hose, Model 3
- 1065131-00-A Battery Coolant Drain Kit
Remove
- Open LH front door, and Lower LH front window.
- Unlock the gateway. See Gateway (Unlock).
- On the touchscreen, tap the Service Mode "wrench" (at the bottom of the touchscreen UI), and then tap , and allow the routine to complete.
- Disconnect the LV battery. See LV Power (Disconnect and Connect).
- Remove the HV battery rear skid plate. See High Voltage Battery Assembly - Skid Plate - Rear (Remove and Replace).
- Position coolant drain container under LH rear of vehicle.
-
Disconnect coolant outlet hose to rear
return hose and plug hoses.
NoteIf the coolant loss is greater then 1L, vacuum fill will be required. See Cooling System - Vacuum Refill.
- Release clip securing coolant hoses to RH shear plate.
- Position coolant drain underneath RH rear of drive unit.
-
Release coolant outlet hose from RDU
heat exchanger and plug both ends.
NoteIf the coolant loss is greater then 1L, vacuum fill will be required. See Cooling System - Vacuum Refill.
- Release coolant outlet hose clip from RDU heat exchanger.
- Remove outlet hose clips from RDU assembly.
- Remove RDU outlet hose from RDU and body.
Install
- Install RDU outlet hose to RDU and body.
- Install outlet hose clips to RDU assembly.
-
Install RDU outlet hose to RDU heat exchanger.
NotePerform push-pull-push test to make sure hose is fully engaged, clean excess coolant from area.
- Install clip securing coolant hoses to RH shear plate.
- Position coolant drain underneath RH rear of HV battery.
-
Remove hose plugs and connect coolant outlet hose to rear return hose.
NoteIf the coolant loss is greater then 1L, vacuum fill will be required. See Cooling System - Vacuum Refill.
- Remove coolant drain container from underneath vehicle.
- Connect the LV battery. See LV Power (Disconnect and Connect).
- Unlock the gateway. See Gateway (Unlock).
- Select , and allow the routine to complete.
-
Select
, and allow the routine to complete.NoteMake sure vehicle is not in Drive, shifting the vehicle into Drive will stop this routine. The test will last approximately 10 mins. The test will vary speeds from 3500-6500 RPM (idle speed = ~1500 RPM) and actuate the valve between series and parallel. If speed hovers at 7000 RPM, it indicates the pump is air locked, perform the vacuum fill again. Continue to add coolant and purge until the coolant level reaches between the NOM and MAX Lines on the bottle.
- Install the HEPA filter assembly. See SERVICE KIT - HEPA AND CARBON FILTERS (Remove and Replace).
- Remove the vehicle from the 2 post lift. See Raise Vehicle - 2 Stands.