HVAC - ACTUATOR 120 DEG (Remove and Install)
Correction code
1810010501
FRT
2.46
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are
created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com.
NOTE: See Personal Protection to make
sure wearing proper PPE when performing the below procedure.
Torque Specifications
Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
---|---|---|---|---|
Screws (x2) that attach the intake actuator to the HVAC assembly |
![]() 1.25 Nm (.9 lbs-ft) |
|
Reuse |
Remove
- Remove the HVAC module assembly. See HVAC MODULE (Remove and Install).
-
Remove the screws (x2) that attach the intake actuator to the HVAC assembly, and then
disconnect the connector.
TIpUse of the following tool(s) is recommended:
- 6 mm socket
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
- Lift up the fixing bracket and remove the intake actuator from the HVAC assembly.
Install
- Align the intake actuator shaft to the slot of the HVAC assembly, and then install the fixing bracket.
-
Connect the connector, and then install the screws (x2) that attach the intake
actuator to the HVAC assembly.1.25 Nm (.9 lbs-ft)TIpUse of the following tool(s) is recommended:
- 6 mm socket
- Digital Torque Screwdriver 0.10Nm - 2.0Nm
- Install the HVAC module assembly. See HVAC MODULE (Remove and Install).