2026-03-02
Busbar - Fast Charge Contactor To Direct Current Busbar - Negative (7-Seat) (Remove and Replace)
Correction code
TBD
FRT
1.86
NOTE: Unless otherwise explicitly stated in the procedure, the correction code and FRT listed above reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are created.
NOTE: See Personal Protection to make sure you
are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy working practices.
- 2026-02-04: Released new procedure.
Remove
- Remove the fast charge contactor cover. See Cover - Fast Charge (7-Seat) (Remove and Replace).
-
Release the location pins (x2), then
remove and discard the patch bolt that attaches the direct current link negative busbar
to the fast charge contactor.
TIpUse of the following tool(s) is recommended:
- SKT, 1/4" SQ DR, 13MM, HV INSULATED
Install
-
Secure the location pins (x2) and
install a new patch bolt that attaches the direct current link negative busbar to the
fast charge contactor.
10 Nm (7.4 lbs-ft) - 180 degreesTIpUse of the following tool(s) is recommended:- SKT, 1/4" SQ DR, 13MM, HV INSULATED
- Install the fast charge contactor cover. See Cover - Fast Charge (7-Seat) (Remove and Replace).