Ancillary Bay Engagement Seal
Correction code
1601010112
FRT
3.30
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate
Times to learn more about FRTs and how
they are created. To provide feedback on FRT values, email ServiceManualFeedback@tesla.com.
NOTE: See Personal Protection
to make sure wearing proper PPE when performing the below procedure.
NOTE: See Ergonomic Precautions for safe and
healthy working practices.
Remove
- Remove the HV battery. See HV Battery (RWD) (Remove and Install).
-
Remove and discard the ancillary bay
engagement seal.
Install
-
Install a new ancillary bay engagement
seal onto the HV battery pack.
- Install the HV battery. See HV Battery (RWD) (Remove and Install).