Cooling System (Partial Refill and Bleed) (Modify)
Correction code 18300000 0.10 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
Procedure
- Open the LH front door and lower the LH front window.
- Unlock the vehicle gateway. See Gateway (Unlock).
-
On the touchscreen, touch
Run to start
the routine.
and select NoteThis routine has a 5-hour limit. After 5 hours, this routine must be performed again.
- Remove the HEPA filter. See HEPA FILTER (Remove and Replace).
- Remove the coolant bottle cap.
-
Fill the coolant to the
proper level.
NoteEnsure that the coolant level is at the "Max" line.
-
Inspect the coolant level
and top off as necessary, and then install the coolant bottle cap.
NoteEnsure that the coolant level is at the "Max" line.
- Install the HEPA filter. See HEPA FILTER (Remove and Replace).
- On the touchscreen, touch Run to start the routine. and select
- Exit Service Mode. See Service Mode.
- Raise the LH front window and close the LH front door.