RT ANGLED POWER OUTLET 12V (Remove and Replace)
Correction code
1530050202
FRT
0.00
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are
created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com.
NOTE: See Personal Protection to make
sure wearing proper PPE when performing the below procedure.
Remove
- Disconnect LV battery and First Responder Loop. See LV Power (Disconnect and Connect).
- Release top LH trunk side trim clips (x4).
- Insert inflatable air bag into the gap.
-
Release angled power outlet 12v connector.
NotePress and pull, to avoid pulling connector by wiring.
- Release angled power outlet 12v female connector from LH trunk side trim.
- Open angled power outlet 12v cover.
-
Remove angled power outlet 12v assembly.
NotePush angled power outlet 12v while simultaneously pull upper mount tab then do the same to clear bottom mount tab. Once cleared successfully the whole assembly will come out smoothly.
Install
-
Install angled power outlet 12v assembly.
NoteInsert connector first then attach mount followed by power outlet itself, push power outlet with cover facing upwards and assembly will secure in place,and ensure fitment is adequate.
- Close angled power outlet 12v cover.
- Secure angled power outlet 12v female connector from LH trunk side trim.
- Secure angled power outlet 12v connector.
- Remove inflatable air bag from the gap.
- Secure top LH trunk side trim clip back to original position.
- Connect LV battery and First Responder Loop. See LV Power (Disconnect and Connect).