Busbar Fast Charge - Input - Negative (Remove and Replace)
Correction code
1630010302
FRT
1.44
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
- 2026-10-14: Updated torque figure and added Hioki test.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
|
Bolt that attaches the positive/negative inlet/DC link fastcharge busbar to the fastcharge contactor |
![]() 15 Nm (11.1 lbs-ft) -180 degrees ![]() 5 Nm (3.7 lbs-ft) +60 degrees |
|
Replace | 1104475-00-F |
Remove
- Remove the fastcharge cover. See Cover - Fast Charge (Remove and Replace).
-
Remove and discard the bolt that
attaches the negative inlet fastcharge busbar to the fastcharge contactor.
TipUse of the following tool(s) is recommended:
- Insulated Ratchet/torque wrench
- Insulated 13 mm socket
- Insulated Torque wrench with angle measurement
Install
-
Install and torque a new bolt that
attaches the negative inlet fastcharge busbar to the fastcharge contactor.
TipUse of the following tool(s) is recommended:
- Insulated Ratchet/torque wrench
- Insulated 13 mm socket
- Insulated Torque wrench with angle measurement
- Perform a zere adjust of the Hioki resistance meter. See Resistance Meter (Zero Adjust).
-
Perform a Hioki impedance test at the negative HV joints of the fastcharge contactor
on the DC link busbar and inlet busbar.
- Install the fastcharge cover. See Cover - Fast Charge (Remove and Replace).