AC Cable - Charge Port to HV Battery (3-Phase) (Remove and Replace)
Correction code 44501402 0.60 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
- 1076921-00-B Insulation Multimeter, Fluke 1507 (NA)
- 1108272-00-B Cap, Logic Conn, Inv, 3DU
- 1130480-00-A Test Probes, Slim, Fluke TP38
- 2023-08-22: Updated the procedure and images.
Only
technicians who have been trained in High Voltage Awareness and
have completed all required certification courses (if applicable) are permitted to
perform this procedure. Proper personal protective equipment
(PPE) and insulating HV gloves with a minimum rating
of class 0 (1000V) must be worn at all times a high voltage
cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness
Care Points
for additional safety
information.
Remove all jewelry (watches, bracelets, rings, necklaces, earrings, ID tags, piercings, etc.) from your person, and all objects (keys, coins, pens, pencils, tools, fasteners, etc.) from your pockets before performing any procedure that exposes you to high voltage.
Proper Personal Protective Equipment (PPE) is required to perform this procedure:
- High Voltage (HV) insulating gloves
- Leather glove protectors
- High voltage glove tester
- Safety glasses
- Electrical hazard rated safety shoes
A glove inflator is the only recommended way to test HV gloves. Both HV gloves must pass testing before beginning this procedure. If either glove does not pass the air check, discard the pair.
Make sure that the HV gloves are not expired. HV gloves can be used up to 12 months after the testing date printed on the glove, but only 6 months after first use even if the gloves are still within the 12-month period.
- Open all doors.
- Lower the LH front window.
- Open the liftgate, hood and charge port door.
- Remove the rear underhood apron. See Underhood Apron - Rear (Remove and Replace).
-
Disconnect 12V power. See 12V/LV Power (Disconnect and Connect).
NoteDo not perform the vehicle isolation procedure at the end of the sub-procedure.
- Perform the charge port voltage check procedure. See Charge Port Voltage Check.
- Remove the LH lower C-pillar trim. See Trim - C-Pillar - Lower - LH (Remove and Replace).
- Remove the rear trunk floor trim. See Trunk Load Floor - Rear (Remove and Replace).
- Remove the front trunk floor trim. See Trunk Load Floor - Front (Remove and Replace).
- Remove the trunk sill trim. See Trim - Sill - Trunk (Remove and Replace).
- Remove the LH trunk load floor bracket. See Bracket - Trunk Load Floor - LH (Remove and Replace).
- Remove the LH trunk pocket bracket. See Bracket - Trunk Pocket - LH (Remove and Replace).
- Remove the LH trunk side trim. See Trim - Side - Trunk - LH (Remove and Replace).
- Remove the LH upper C-pillar trim. See Trim - C-Pillar - Upper - LH (Remove and Replace).
- Remove the LH C-Pillar bracket. See Bracket - C-Pillar - LH (Remove and Replace).
- Carefully pull out the locking tab, and then disconnect the logic connector from the charge port.
- Push the locking tab upward, and then disconnect the AC cable from the charge port.
-
Release the red locking tab, rotate the black lever upwards, and then
disconnect the AC cable from the ancillary bay HV header.
- Take note of how the AC cable is routed in relation to the charge port busbar and LH body harness.
- Remove the clips (x3) and zip ties (x5) that attach the AC cable to the charge port busbar.
- Remove the AC cable from the vehicle, sliding the cable under the body harness as needed.
Install
- Position the AC cable in the vehicle, sliding the cable under the body harness as needed.
- Install the clips (x3) and zip ties (x5) to attach the AC cable to the charge port busbar.
- Connect the AC cable to the ancillary bay HV header, rotate the black lever downward, and then engage the red locking tab.
- Connect the AC cable connector to the charge port, and then slide the locking tab downward.
- Connect the logic connector to the charge port, and then push in the locking tab.
- Install the LH C-Pillar bracket. See Bracket - C-Pillar - LH (Remove and Replace).
- Install the LH upper C-pillar trim. See Trim - C-Pillar - Upper - LH (Remove and Replace).
- Install the LH trunk side trim. See Trim - Side - Trunk - LH (Remove and Replace).
- Install the LH trunk pocket bracket. See Bracket - Trunk Pocket - LH (Remove and Replace).
- Install the LH load floor bracket. See Bracket - Trunk Load Floor - LH (Remove and Replace).
- Install the trunk sill trim. See Trim - Sill - Trunk (Remove and Replace).
- Install the front trunk floor trim. See Trunk Load Floor - Front (Remove and Replace).
- Install the rear trunk floor trim. See Trunk Load Floor - Rear (Remove and Replace).
- Reconnect 12V power. See 12V/LV Power (Disconnect and Connect).
- Close the liftgate.
- Close the charge port door.
- Close all doors.