31/01/2024 23:18:32

Sensor - Pressure and Temperature (PT) - Low Pressure (Remove and Replace)

Correction code 18400402 0.54NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.

  • 2023-04-04: Updated A/C oil type to be used with reference to Fluids and Capacities for A/C oil specifications.
  • 2024-02-01: Updated the way of performing the routines from using Toolbox to using the touchscreen.

Torque Specifications

Table 1. Torque Specifications: Sensor - Pressure and Temperature (PT) - Low Pressure (Remove and Replace)
Description Torque Value Recommended Tools Reuse/Replace Notes
Low Pressure and Temperature Sensor
9 Nm (6.6 lbs-ft)
  • 1565836-00-A - GEN 1 P/T SENSOR SOCKET, 21MM
  • 1600833-00-A - GEN 2 P/T SENSOR SOCKET, 24MM
  • Flex head ratchet/flex head torque wrench
  • 3 in extension
N/A
  • Only use the special socket to remove and install this sensor
  • The sensor screws directly into the supermanifold.

Remove

  1. Open the LH front door and lower the LH front window.
  2. Place the vehicle in Service Mode by using the touchscreen. See Service Mode.
  3. Remove the underhood storage unit. See Underhood Storage Unit (Remove and Replace).
  4. Remove the HEPA filter assembly. See Assembly - Filter - HEPA (Remove and Install).
  5. Unlock the vehicle gateway. See Gateway (Unlock).
  6. On the touchscreen, tap the Service Mode "wrench" (at the bottom of the touchscreen UI), and then tap Thermal > Refrigerant System > Start Thermal Fill Drain (Refrigerant only) > Run, and allow the routine to complete.
  7. Recover the A/C refrigerant (refrigerant only). See GUID-C757523B-9718-45E7-BAF8-ABC5563F65AC.html#TASK_HWT_DLP_WNB.
    Informational PurposesAn informational icon, calling your attention
    Note
    Completely recover the refrigerant before continuing this procedure.
  8. Release the locking tab, and then disconnect the electrical connector from the low pressure temperature sensor.
    Warning IconA warning icon, calling your attention to a possibly risky situation
    CAUTION
    DO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
  9. Use the P/T sensor socket to remove the low pressure temperature sensor from the supermanifold.
    Warning IconA warning icon, calling your attention to a possibly risky situation
    CAUTION
    Use only hand tools to remove the PT sensor. Impact or power tools will break the threads.
    Warning IconA warning icon, calling your attention to a possibly risky situation
    CAUTION
    Use only the P/T sensor socket to remove the sensor. Using other tools can damage the sensor.
    Informational PurposesAn informational icon, calling your attention
    Note
    For Sensata sensors, use the 24mm thin wall P/T sensor socket (1600833-00-A). For Bridgeport sensors, use the 21mm P/T sensor socket (1565836-00-A).
    Tip: Use of the following tool(s) is recommended:
    • 1565836-00-A - GEN 1 P/T SENSOR SOCKET, 21MM
    • 1600833-00-A - GEN 2 P/T SENSOR SOCKET, 24MM
    • Flex head ratchet/flex head torque wrench
    • 3 in extension
  10. Record the part numbers and serial numbers of the old and new sensors in the repair order.

Install

  1. Lubricate the new low pressure temperature sensor threads and O-ring with the appropriate A/C oil. See Fluids and Capacities for A/C oil specifications.
  2. Install and hand-tighten the low pressure temperature sensor until the sensor O-ring just makes contact with the Supermanifold.
    Informational PurposesAn informational icon, calling your attention
    Note
    Use an inspection mirror to visualize this and subsequent steps.
  3. Manually back off and tighten the low pressure temperature sensor in an incremental manner so that the sensor O-ring properly slides into the chamfer in the Supermanifold.
  4. If the low pressure temperature sensor O-ring appears to pinch, or no longer slides into the chamfer, stop and reverse thread the sensor until the O-ring no longer appears to be pinched.
  5. Continue to back off and tighten the low pressure temperature sensor until the O-ring slides completely into the chamfer and is no longer visible.
    Informational PurposesAn informational icon, calling your attention
    Note
    There should be no gap, and the sensor body should be bottomed out against the Supermanifold.
  6. Use the P/T sensor socket to tighten the low pressure temperature sensor to the specified torque value.
    9 Nm (6.6 lbs-ft)
    Warning IconA warning icon, calling your attention to a possibly risky situation
    CAUTION
    Use only hand tools to install the PT sensor. Impact or power tools will break the threads.
    Warning IconA warning icon, calling your attention to a possibly risky situation
    CAUTION
    Use only the P/T sensor socket to install the sensor. Using other tools can damage the sensor.
    Informational PurposesAn informational icon, calling your attention
    Note
    For Sensata sensors, use the 24mm thin wall P/T sensor socket (1600833-00-A). For Bridgeport sensors, use the 21mm P/T sensor socket (1565836-00-A).
    Tip: Use of the following tool(s) is recommended:
    • 1565836-00-A - GEN 1 P/T SENSOR SOCKET, 21MM
    • 1600833-00-A - GEN 2 P/T SENSOR SOCKET, 24MM
    • Flex head ratchet/flex head torque wrench
    • 3 in extension
  7. Connect the electrical harness to the low pressure temperature sensor, and then engage the locking tab.
    Warning IconA warning icon, calling your attention to a possibly risky situation
    CAUTION
    Push the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
  8. Perform the vacuum leak test and oil injection. See Vacuum Leak Test and Oil Injection.
  9. Recharge the A/C refrigerant. See GUID-C757523B-9718-45E7-BAF8-ABC5563F65AC.html#TASK_DTN_JLP_WNB.
    Informational PurposesAn informational icon, calling your attention
    Note
    Do not disconnect the laptop from the vehicle yet.
  10. If a refrigerant leak detector is available, make sure that there is no leak at the low pressure temperature sensor.
  11. On the touchscreen, tap the Service Mode "wrench" (at the bottom of the touchscreen UI), and then tap Thermal > Sensors and Valves > Run Heat Pump Commissioning > Run, and close once the routine is passed.
  12. Tap Actions > Test Thermal Performance > Run, and close once the routine is passed.
  13. Tap Actions > Test HVAC Performance > Run, and close once the routine is passed.
  14. Exit Service Mode. See Service Mode.
  15. Install the HEPA filter assembly. See Assembly - Filter - HEPA (Remove and Install).
  16. Install the underhood storage unit. See Underhood Storage Unit (Remove and Replace).