2023-11-02
LV Maintainer (Connect and Disconnect)
Correction code
17010500
0.05
NOTE: Unless otherwise explicitly
stated in the procedure, the above correction code and FRT reflect all of the work
required to perform this procedure, including the linked procedures. Do not stack correction codes unless
explicitly told to do so.NOTE: See Flat Rate
Times to learn more about FRTs and how they are created. To provide feedback on
FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when
performing the below procedure.
- 2023-10-31: Updated the location to attach the maintainer's negative clamp with new images attached.
Connect
- On the touchscreen, select the badge icon in Controls > Software for four seconds, and then type "service" into the dialog box to place the vehicle in service mode.
- Release the positive terminal cover.
- Secure the LV maintainer positive terminal to the jump post.
- Secure the LV maintainer negative terminal to the bolt located between the brake fluid reservoir and front trunk.
-
Connect the LV maintainer to a power supply, and then power on.
CAUTIONNever have a LV maintainer and the LV battery simultaneously connected for any extended period of time.
-
Lift the green locking tab upward, slide the black connector lock outwards, and then
pull up to release the LV battery connector.
NoteKeep the FRL connected.
Disconnect
- Position the LV battery connector onto the LV battery, push the black connector lock inwards to secure, and then press the green locking tab downward to engage when the connector is fully seated.
- Power off the LV maintainer.
- Release the negative terminal connection from the vehicle first, and then release the positive terminal.
- Secure the positive terminal cover.
-
Confirm that the LV battery State Of
Charge (SOC) is above 73% and Battery State is Charge or Standby.
NoteIf the LV battery SOC is below 73% confirm that Battery State is Charge and Pack Current is positive, Via Tesla Garage > LV.