20/05/2021 17:08:00

Adapter - Bleeder Duct - Instrument Panel (Remove and Replace)

Correction code 18100012 1.98 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.

Remove

  1. Remove the instrument panel carrier. See IP Carrier (Remove and Install).
  2. Remove the bolts that attach the touchscreen brackets, and remove the brackets from the vehicle.
    Tip: Use of the following tool(s) is recommended:
    • T30 socket
    • Flex head ratchet / flex head torque wrench
    • 6 in extension
  3. Release the clips that attach the bleeder duct adapter to the HVAC assembly, and remove the bleeder duct from the vehicle.

Install

  1. Install the bleeder duct adapter into the HVAC assembly.
  2. Position the touchscreen brackets onto the instrument panel, and then install the bolts that attach the touchscreen brackets to the instrument panel.
    12 Nm (8.8 lbs-ft)
    Tip: Use of the following tool(s) is recommended:
    • T30 socket
    • Flex head ratchet / flex head torque wrench
    • 6 in extension
  3. Install the instrument panel carrier. See IP Carrier (Remove and Install).