Contactor - Fast Charge - HV Battery (3-Phase) (Structural Pack) (Remove and Replace)
Correction code 16302612 2.28 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
- 1057602-00-A Ratchet, 1/4" Sq Dr, HV Insulated
- 1057603-00-A Ext Bar, Wobble, 1/4" Dr, HV Insulated
- 1057606-00-A Skt, 1/4" Sq Dr, 13mm, HV Insulated
- 1057607-00-A Magnet, Flexible, HV Insulated, 18"
- 1059330-00-B Skt, 1/4in Dr, 5-Lobe Torx Plus External
- 1076927-00-A Resistance meter, microohm, Hioki RM 3548
Only technicians who have been trained in High Voltage Awareness and have completed all required certification courses (if applicable) are permitted to perform this procedure. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points
for additional safety information.
Torque Specifications
Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
---|---|---|---|---|
Bolt that attaches the DC inlet positive busbar to the ancillary bay |
|
|
Replace | |
Bolt that attaches the DC inlet negative busbar to the ancillary bay |
|
|
Replace | |
Bolts (x2) that attach the FC positive outlet jumper to the ancillary bay |
|
|
Replace | |
Bolts (x2) that attach the FC negative outlet jumper to the ancillary bay |
|
|
Replace | |
Bolts (x3) that attach the HV battery fast charge contactor to the ancillary bay |
|
|
Reuse |
Remove
- Remove the ancillary bay cover. See Cover - Ancillary Bay (Structural Pack) (3-Phase) (Remove and Replace).
- Remove the pyrotechnic battery disconnect. See Pyrotechnic Battery Disconnect (Structural Pack) (Remove and Install).
- Release the clip that attaches the DC fast charge HVIL connector to the tray.
- Release the connector lock, and then disconnect the ancillary bay harness from the HV connector harness.
- Slide the DC fast charge HV connector straight up to remove it from the assembly.
- Release the locking tab, and then disconnect the CPIL connector.
-
Release the clip that
attaches the fast charge contactor harness branch to the tray.
NoteThe clip location may vary.
-
Disconnect the fast charge
contactor connector.
NotePush on both side of connector to release the tabs, and then pull upward to disconnect.
- Release the clips (x4) that attach the HV battery AC filter harness to the ancillary bay.
- Release the locking tab, and then disconnect the HV battery AC filter harness connector.
- Remove the HV battery AC filter harness from the ancillary bay.
- Release the securing tabs (x3), and then remove the fast charge contactor cover.
-
Remove and discard the bolt
that attaches the DC inlet positive busbar to the ancillary bay.
Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Remove and discard the bolt
that attaches the DC inlet negative busbar to the ancillary bay.
Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
- Lift the HV battery fast charge positive inlet busbar straight up to remove it.
- Lift the HV battery fast charge negative inlet busbar straight up to remove it.
-
Remove and discard the bolts
(x2) that attach the FC positive outlet jumper to the ancillary bay, and then
remove the FC positive outlet jumper from the ancillary bay.
Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Remove and discard the bolts
(x2) that attach the FC negative outlet jumper to the ancillary bay, and then
remove the FC negative outlet jumper from the ancillary bay.
Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Remove the bolts (x3) that
attach the HV battery fast charge contactor to the ancillary bay, and then
remove the HV battery fast charge contactor from the ancillary bay.
Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- Socket External Torx 1/4in Dr. E8
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
Install
- Perform a zero adjust of the Hioki resistance meter in preparation to measure resistances later in this procedure. See Resistance Meter (Zero Adjust).
-
Install the bolts (x3) that
attach the HV battery fast charge contactor to the ancillary bay.Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- Socket External Torx 1/4in Dr. E8
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Use IPA wipes to clean the
high voltage mating surfaces of the fast charge contactor and the positive
and negative DC inlet and outlet busbars.
NoteAllow 1 minute dry time.
-
Position the FC negative
outlet jumper onto the ancillary bay, and then install new bolts (x2) that
attach the FC negative outlet jumper to the ancillary bay.NoteTighten the bolt to 15 Nm, back off 180 degrees, then torque to 5 Nm +60 degrees.Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Position the FC positive
outlet jumper onto the ancillary bay, and then install new bolts (x2) that
attach the FC positive outlet jumper to the ancillary bay.NoteTighten the bolt to 15 Nm, back off 180 degrees, then torque to 5 Nm +60 degrees.Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Use a Hioki resistance meter
to measure the resistance at the HV joint between the FC negative outlet
jumper busbar and the DC negative link busbar.
NoteThe maximum acceptable resistance is 0.060 mΩ (60 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
-
Use a Hioki resistance meter to measure the resistance at the HV joint
between the FC contactor negative joint to the FC negative outlet jumper
busbar.
NoteThe maximum acceptable resistance is 0.150 mΩ (150 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
-
Use a Hioki resistance meter
to measure the resistance at the HV joint between the FC positive outlet
jumper busbar to the DC positive link busbar.
NoteThe maximum acceptable resistance is 0.060 mΩ (60 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
-
Use a Hioki resistance meter to measure the resistance at the HV joint
between the FC contactor positive joint to the FC positive outlet jumper
busbar.
NoteThe maximum acceptable resistance is 0.150 mΩ (150 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
- Position the DC inlet negative busbar onto the ancillary bay.
- Position the DC inlet positive busbar onto the ancillary bay.
-
Install new bolt that
attaches the DC inlet negative busbar to the ancillary bay.NoteTighten the bolt to 15 Nm, back off 180 degrees, then torque to 5 Nm +60 degrees.Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Install new bolt that
attaches the DC inlet positive busbar to the ancillary bay.NoteTighten the bolt to 15 Nm, back off 180 degrees, then torque to 5 Nm +60 degrees.Tip: Use of the following tool(s) is recommended:
- Insulated tools:
- 13 mm socket
- Magnetic pick up tool
- Extension 1/4 Dr. Wobble 10.5"
- Ratchet/torque wrench
- Insulated tools:
-
Use a Hioki resistance meter
to measure the resistance at the HV joint between the FC contactor positive
joint and the positive DC inlet busbar.
NoteThe maximum acceptable resistance is 0.150 mΩ (150 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
-
Use a Hioki resistance meter
to measure the resistance at the HV joint between the FC contactor negative
joint and the negative DC inlet busbar.
NoteThe maximum acceptable resistance is 0.150 mΩ (150 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
- Install the fast charge contactor cover and make sure the the tabs (x3) are properly secured.
- Connect the HV battery AC filter harness connector to the ancillary bay.
- Install the clips (x4) that attach the HV battery AC filter harness to the ancillary bay.
- Connect the fast charge contactor connector.
- Install the clip that attaches the fast charge contactor harness branch to the tray.
-
Connect the CPIL
connector.
NoteSlide the CPIL connector back into the slot, and then engage the connector locking tab.
-
Install the DC fast charge
HV connector.
CAUTIONBe careful not to pinch the harness.
-
Secure the DC fast charge
HVIL connector to the tray.
- Connect the ancillary bay harness to the HV connector harness, and then engage the connector lock.
- Install the pyrotechnic battery disconnect. See Pyrotechnic Battery Disconnect (Structural Pack) (Remove and Install).
- Install the ancillary bay cover. See Cover - Ancillary Bay (Structural Pack) (3-Phase) (Remove and Replace).
-
Verify the operation of the charging system.
NoteConfirm the AC and DC charging functions are OK.