15/12/2023 01:30:07

Harness - AC Filter - HV Battery (3-Phase) (Structural Pack) (Remove and Replace)

Correction code 16305412 1.62 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.

Warning IconA warning icon, calling your attention to a possibly risky situation
Warning
Remove all jewelry (watches, bracelets, rings, necklaces, earrings, ID tags, piercings, etc.) from your person, and all objects (keys, coins, pens, pencils, tools, fasteners, etc.) from your pockets before performing any procedure that exposes you to high voltage.
Warning IconA warning icon, calling your attention to a possibly risky situation
Warning
If corrective eyewear is necessary to safely perform any procedure, make sure that the eyewear is securely restrained to the head and cannot fall off.
Warning IconA warning icon, calling your attention to a possibly risky situation
Warning

Only technicians who have been trained in High Voltage Awareness and have completed all required certification courses (if applicable) are permitted to perform this procedure. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points for additional safety information.

Remove

  1. Remove the ancillary bay cover. See Cover - Ancillary Bay (Structural Pack) (Remove and Replace).
  2. Release the locking tab, and then disconnect the charge inlet connector.
  3. Release the locking tab, and then disconnect the CPIL connector.
  4. Release the clips (x3) that attach the HV battery AC filter harness to the ancillary bay.
  5. Release the locking tab, and then disconnect the HV battery AC filter harness connector.
  6. Remove the HV battery AC filter harness from the ancillary bay.

Install

  1. Connect the HV battery AC filter harness connector to the ancillary bay.
  2. Install the clips (x3) that attach the HV battery AC filter harness to the ancillary bay.
  3. Connect the CPIL connector.
  4. Connect the charge inlet connector.
  5. Install the ancillary bay cover. See Cover - Ancillary Bay (Structural Pack) (Remove and Replace).