09/12/2024 00:58:40
Sensor - Relative Humidity and Temperature (HW3) (Remove and Install)
Correction code 10206001 0.55 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
Remove
- Remove the relative humidity and temperature sensor. See Sensor - Relative Humidity and Temperature (Remove and Replace).
Replace Graphene Block
- Prepare then put on an ESD wrist strap. See Electrostatic Discharge Tooling.
-
Remove the graphene foam
block from the temperature and humidity sensor.
NoteIf needed, apply heat to area around the adhesive and gently lift the block up with tweezers.
- Use an IPA wipe to clean the area where the temperature and humidity sensor foam block will rest, and allow 1 minute dry time.
-
Secure the foam block
locator tool onto the temperature and humidity sensor.
NoteAlign the datum with the board hole.Tip: Use of the following tool(s) is recommended:
- M3 THS Foam Fixture - 1727102-00-A
-
Use tweeters to install a
new graphene foam block (1110914-00-D) onto the temperature and humidity
sensor.
NoteEnsure the foam is flush against the tool.
- Remove the ESD wrist strap.
Install
- Install the relative humidity and temperature sensor. See Sensor - Relative Humidity and Temperature (Remove and Replace).