2026-05-29

Sensor - Relative Humidity and Temperature (Remove and Install)

Correction code See below for correction codes and FRTs 0.30 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure. NOTE: See Ergonomic Precautions for safe and healthy working practices.

  • 2026-05-29: Added correction codes for HW3 and HW4 respectively.

Correction code information:

  • Sensor - Relative Humidity and Temperature (HW3) (Remove and Install), 10207001, FRT: 0.55
  • Sensor - Relative Humidity and Temperature (HW4) (Remove and Install), 10206001, FRT: 0.30

Replace Graphene Block

  1. Prepare then put on an ESD wrist strap. See Electrostatic Discharge Tooling.
  2. Remove the graphene foam block from the temperature and humidity sensor.
    Informational PurposesAn informational icon, calling your attention
    Note
    If needed, apply heat to area around the adhesive and gently lift the block up with tweezers.
  3. Use an IPA wipe to clean the area where the temperature and humidity sensor foam block will rest, and allow 1 minute dry time.
  4. Secure the foam block locator tool onto the temperature and humidity sensor.
    Informational PurposesAn informational icon, calling your attention
    Note
    Align the datum with the board hole.
    Informational PurposesAn informational icon, calling your attention
    TIp
    Use of the following tool(s) is recommended:
    • M3 THS Foam Fixture - 1727102-00-A
  5. Use tweeters to install a new graphene foam block (1110914-00-D) onto the temperature and humidity sensor.
    Informational PurposesAn informational icon, calling your attention
    Note
    Ensure the foam is flush against the tool.
  6. Remove the ESD wrist strap.