Applique - Roof - LH (Standalone) (Rework)
Correction code
NA
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
-
Prepare work area
NoteLay down a soft material to prevent scratching the A surface
-
Identify center tabs of roof applique
NoteCenter tabs have narrower channel then outer tabs
-
Enlarge opening of roof applique center tabs
Note4x tabs, Use a rotary tool with a narrow grinding bit, Set rotary tool to low speed then enlarge opening to 5mm, Ensure opening in ground flush to bottom surface, Clean any debris once complete