2025-11-04
Striker - Powergate (Remove and Install)
Correction code
1133116091
1133116092
FRT
0.06
NOTE: Unless otherwise explicitly stated in the procedure, the correction code and FRT listed above reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are created.
NOTE: See Personal Protection to make sure you
are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy working practices.
Warning
This procedure is a DRAFT.
Although it has been validated, Warnings and Cautions might be missing. Follow safety
requirements and use extreme caution when working on or near High Voltage systems and
components.
Remove
- Open the powered frunk.
-
Remove the bolts (x2) that attach the
powergate striker to the powergate, and then remove the striker from the vehicle.
15 Nm (11.1 lbs-ft)CAUTIONDo not use power tools to remove the fasteners. Use hand tools only.TIpUse of the following tool(s) is recommended:- Torx T40 socket
Install
-
Position the powergate striker onto the powergate, and then install the bolts (x2)
that attach the striker to the powergate.
15 Nm (11.1 lbs-ft)CAUTIONDo not use power tools to install the fasteners. Use hand tools only.TIpUse of the following tool(s) is recommended:- Torx T40 socket
- Close the powered frunk.