13/05/2024 09:14:05
Air Suspension - Pressurize / Depressurize - Full System
Correction code 31101500 FRT 0.24 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
- 2024-05-13: Corrected psi value to 261 psi (18 bar).
Deflate All
- Raise and support the vehicle on a 2 post lift. See .Raise Vehicle - 2 Post Lift.
- Open the LH front door and lower the LH front window.
- Put the vehicle in Service Mode. See Service Mode.
- Unlock the vehicle gateway. See Gateway (Unlock).
-
Deflate the TAS system through the
vehicle touchscreen.
NoteTouch Service > Chassis > Suspension > Service > Deflate All, and then touch Run. Close it once the routine passed.
- Return to the procedure that required the air suspension system to be deflated.
Refill the Reservoir
- Remove the RH rear fender flare. See Front and Rear Garnish - Rear Fender Flare - RH (Remove and Install).
- Remove the RH rear fender flare carrier. See Front and Rear Garnish - Carrier - Rear Fender Flare Aft - RH (Remove and Install).
-
Set up nitrogen tank kit
(1083876-00-A) to fill the air reservoir.
NoteVerify valves are set to closed position on the tank, the regulator, and the air line.
-
Connect the nitrogen tank hose onto
the air reservoir fill port.
-
Open the valve on the nitrogen tank,
and then set pressure using the regulator.
NoteSlowly open valve and adjust the regulator. Verify the pressure is set to 18 bar (261 psi).
-
Open the valve on the nitrogen tank
hose.
-
Verify that pressure holds on the
regulator valve gauge.
Note18 bar (261 psi)NoteIf the pressure does not hold, there may be a leak present.
-
Close the valve on the nitrogen tank
hose.
-
Close the valve on the nitrogen
tank.
-
Close the pressure regulator valve on
the nitrogen tank to release pressure in lines.
-
Disconnect the nitrogen tank hose from
the air reservoir fill port.
- Install the RH rear fender flare carrier. See Front and Rear Garnish - Carrier - Rear Fender Flare Aft - RH (Remove and Install).
- Install the RH rear fender flare. See Front and Rear Garnish - Rear Fender Flare - RH (Remove and Install).
-
Put the vehicle in TAS normal mode
using the vehicle touchscreen.
NoteTouch Service > Chassis > Suspension > Normal.
- Remove the vehicle from the lift. See Raise Vehicle - 2 Post Lift.
-
Verify the operation of the air
suspension.
NoteCycle the ride height through the vehicle touchscreen: Controls > Suspension > Low to Very High.NoteAll doors must be closed to allow ride height to cycle.NoteSet the air suspension back to ''Standard'' after verification.
- Exit Service Mode. See Service Mode.
- Raise the LH front window and close the LH front door.