Safety Cap - Busbar - Charge Port to HV Battery (Global) (Remove and Replace)
Correction code 44015122 0.30 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure proper PPE is worn when performing the below procedure.
- 2023-07-20: Reorganized the procedure.
- 1076921-00-B Insulation Multimeter, Fluke 1507 (NA)
- 1076921-00-A Insulation Multimeter, Fluke 1587 (EMEA)
- 1076921-01-B Insulation Multimeter, Fluke 1508 (APAC)
- 1130480-00-A Test Probes, Slim, Fluke TP38
- High Voltage (HV) insulating gloves
- Leather glove protectors
- High voltage glove tester
- Safety glasses
- Electrical hazard rated safety shoes
High Voltage Awareness Care Pointsfor additional glove and safety information.
- North America: HV gloves can be used up to 12 months after the testing date printed on the glove, but only 6 months after first use even if the gloves are still within the 12 month period. If the gloves were not put into service during the 12-month period following the testing date, they must be retested before being put into service.
- Europe: HV gloves have no expiration date and may be used if they pass the pressure assessment and the periodic inspection.
- Asia Pacific: Follow the
expiration date stated by the HV glove manufacturer, and:
- o China only: Test the gloves every 6 months according to GB/T 17622.
Remove
- Perform the charge port voltage check. See Charge Port Voltage Check.
- Remove the LH trunk side trim. See Trim - Side - Trunk - LH (Remove and Replace).
-
Disconnect the charge port electrical
connector.
NoteCarefully remove the white locking tab, press the tab to disconnect the electrical connector from the charge port.
-
Release the hooks (x2) to remove the
safety cap from the charge port.
Install
-
Install the charge port safety
cap.
-
Connect the charge port electrical
connector.
Note1x connector, Fully engage connection and white locking tab, The connector is intended to lock the safety cap in place
- Install the LH trunk sill trim. See Trim - Side - Trunk - LH (Remove and Replace).
- Connect LV power. See LV Power (Disconnect and Connect).