Inverter Air Leak Test (On Table)
Correction code 40202030 0.05 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure proper PPE is worn when performing the below procedure.
Procedure
- Inspect the condition of the leak test adapter O-ring, and replace if damaged, loose, or missing.
- Install the leak test adapter plug into the drive unit inverter logic connector.
- Inspect the condition of the leak test adapter O-ring, and replace if damaged, loose, or missing.
- Install the leak test adapter onto the drive unit inverter HV header.
-
Connect the enclosure leak tester hose
to the leak test adapter.
NoteRestrain the enclosure leak tester hose so that it will not tug the leak test adapter off of the drive unit inverter HV header.
- Turn valve P2 (left) and valve P1 (right) to the closed (vertical) position on the enclosure leak tester.
- Turn the knob on the regulator to the fully closed setting.
- Connect the supply compressed air line to the enclosure leak tester.
- Turn valve P1 (right) to the open (horizontal) position and slowly adjust the regulator so that 1 psi is displayed on the gauge.
- Slowly turn valve P2 (left) to the open (horizontal) position and allow air to enter the drive unit inverter.
- Allow 45 seconds for the pressure to stabilize.
- Turn valve P1 (right) to the close (vertical) position.
- Record the beginning pressure value and start a 60 second timer.
-
After 60 seconds has elapsed, record
the end pressure value, and then substract the end pressure value from the beginning
pressure value: the acceptable pressure difference is 0.2 psi or less.
- If the pressure difference is 0.2 psi or less, continue the procedure.
- If the pressure difference is more than 0.2 psi, inspect the drive unit inverter for leaks, check the hose, adapter, and plug fittings, turn valve P2 (left) to the close (vertical) position, turn valve P1 (right) to the open (horizontal) position, check the regulator pressure and retest from step 9. If the difference is still more than 0.2 psi, refer to Toolbox article 6415200 (Tesla Internal) or 6415200 (External parties).
- Disconnect the supply compressed air line from the enclosure leak tester.
- Slowly turn valve P1 (right) to the open (horizontal) position, and allow air to exit the drive unit inverter.
- Disconnect the enclosure leak tester hose from the leak test adapter.
-
Remove the leak test adapter from the
drive unit inverter HV header.
-
Remove the leak test adapter plug from
the drive unit inverter logic connector.