Light - Brake - High Mounted (Remove and Replace)

Correction code 17402502 1.32 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure proper PPE is worn when performing the below procedure.

  • 2023-11-21: Updated template availability from external link.
Warning IconA warning icon, calling your attention to a possibly risky situation
CAUTION
For Europe only: Only technicians who have been trained in working with diisocyanates and have completed all required certification courses are permitted to perform procedures using urethane and other products containing diisocyanates. Proper personal protective equipment (PPE) must be worn when working with products containing diisocyanates.

Install

  1. Inspect the liftgate glass for any damage that is not reworkable.
    Informational PurposesAn informational icon, calling your attention
    Note
    Replace the liftgate glass if there is any damage that cannot be rectified.
  2. Use an isopropyl alcohol (IPA) wipe to clean the CHMSL mounting location on the liftgate glass.
    Informational PurposesAn informational icon, calling your attention
    Note
    Allow the surface to dry for at least one minute.
  3. Use an isopropyl alcohol (IPA) wipe to clean the urethane path on the liftgate glass.
    Informational PurposesAn informational icon, calling your attention
    Note
    Allow the surface to dry for at least one minute.
  4. Use an isopropyl alcohol (IPA) wipe to clean the urethane path on liftgate assembly.
    Informational PurposesAn informational icon, calling your attention
    Note
    Allow the surface to dry for at least one minute.
  5. Print out the CHMSL template and cut it out.
    Informational PurposesAn informational icon, calling your attention
    Note
    The template is available here. When correctly sized, the square should print at 1 inch square.
  6. Place the CHMSL templates on the upper corner of the liftgate glass, and then secure the template with tape.
  7. Remove the red tape covers from the CHMSL.
  8. Position the CHMSL to upper corners of template, and then apply pressure to the CHMSL to adhere the 3M tape to liftgate glass.
  9. Remove the CHMSL templates from liftgate glass.
  10. Use tape to secure the CHMSL harness to the liftgate glass.
  11. Install the liftgate glass. See Liftgate Glass (Remove and Install).