17/06/2022 13:30:58

Sensor - Air Temperature - Duct - Defrost (Remove and Replace)

Correction code 18109302 1.02 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure proper PPE is worn when performing the below procedure.

Install

  1. Position the defrost duct air temperature sensor into the HVAC assembly, connect the electrical connector, and then install the sensor into the HVAC assembly.
    Informational PurposesAn informational icon, calling your attention
    Note
    Connect the electrical connector first, and then ensure the sensor is fully seated into the HVAC case.
  2. Install the driver instrument panel duct. See Duct - Instrument Panel - Driver (Remove and Replace).
  3. Install the instrument panel sub-assembly. See Harness - Sub-Assembly - Instrument Panel (Remove and Replace).
  4. Raise the front windows and close the LH front door.