2026-08-21

LH Clevis Motor Mount and RH Bushing Carrier - Set (Remove and Replace)

Correction code 39010102302 FRT 7.50 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and its associated FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See Personal Protection to make sure you are wearing proper PPE when performing the procedure below. NOTE: See Ergonomic Precautions for safe and healthy working practices.

Warning
This procedure is a DRAFT. Although it has been validated, Warnings and Cautions might be missing. Follow safety requirements and use extreme caution when working on or near High Voltage systems and components.
  • 2026-03-04: Released new procedure.

Install

  1. Release bolts securing RHS bushing carrier and remove assembly
    Note
    4x bolts, EP20, 60 Nm + 50 Degrees, Verify FDU strap is secured properly, Recommend assistance to prevent unit from tilting
  2. Install RHS bushing carrier and secure bolts
    Note
    4x bolts, EP20, 60 Nm + 50, Verify FDU strap is secured properly, Recommend assistance to prevent unit from tilting, Torque bolts down in the sequence shown
  3. Remove bolts from LH FDU clevis mount to body
    Note
    2x bolts, E14, 65 Nm
  4. Release bolts securing clevis to LH motor mount assembly
    Note
    2x bolts, E14, 92 Nm
  5. Release bolts securing LH motor mount assembly to FDU
    Note
    3x bolts, E14, 35 Nm + 55 degrees
  6. Separate clevis mount from LH motor mount assembly
    Note
    2x bolts, E14, 92 Nm
  7. Install bolts securing LH motor mount assembly to FDU
    Note
    3x bolts, E14, 35 Nm + 55 degrees, Install bolts and perform final torque in the sequence shown