Actuator - Intake (Heat Pump) (Remove and Replace)
Correction code
18102012
FRT
4.38
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
Remove
- Remove the HVAC assembly. See HVAC Assembly (Heat Pump) (Remove and Replace).
-
Disconnect the electrical harness from the intake actuator connector.
-
Remove the screws (x2) that
attach the intake actuator to the HVAC module, and then remove the actuator
from the HVAC module.
2.3 Nm (1.7 lbs-ft)NoteUse of the following tool(s) is recommended:- 6 mm socket
- 4 in extension
- Flex head ratchet/flex head torque wrench
Install
Installation procedure is the reverse of removal.