Sensor - Pressure and Temperature (PT) - High Pressure (Non-Heat Pump) (Remove and Replace)

Correction code 18205502 1.44 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.

Install

Installation procedure is the reverse of removal, except for the following:

  • Perform an A/C refrigerant recharge. See A/C Refrigerant (Recovery and Recharge).
  • Connect a laptop with Toolbox 3 to the vehicle, and then:
    1. Search for "reset vcfront" in the Actions/Autodiag tab, select TEST-RESET_VCFRONTvia Toolbox: (link)via Service Mode Plus:
      • Low Voltage ➜ Power Distribution ➜ Reset VCFRONT
      • Mid Voltage ➜ Power Distribution ➜ Reset VCFRONT
      , click Run and allow the routine to complete.
    2. Search for "thermal" in the Actions/Autodiag tab, select TEST-SELF_VCFRONT_X_THERMAL-PERFORMANCEvia Toolbox: (link)via Service Mode: Thermal ➜ Actions ➜ Test Thermal Performancevia Service Mode Plus:
      • Drive Inverter ➜ Front Drive Inverter Replacement ➜ Thermal System Test
      • Drive Inverter ➜ Rear Drive Inverter Replacement ➜ Thermal System Test
      • Drive Inverter ➜ Rear Left Drive Inverter Replacement ➜ Thermal System Test
      • Drive Inverter ➜ Rear Right Drive Inverter Replacement ➜ Thermal System Test
      • Drive Unit ➜ Front Drive Unit Replacement ➜ Thermal System Test
      • Drive Unit ➜ Rear Drive Unit Replacement ➜ Thermal System Test
      , click Run and allow the routine to complete.