Insulator - FastCharge - Lower (Remove and Replace)
Correction code
1630010232
FRT
1.74
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and FRT
listed above reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times
to learn more about FRTs and how they are created.
NOTE: See Personal Protection
to make sure you are wearing proper PPE when performing the procedure
below.
NOTE:
See Ergonomic Precautions for
safe and healthy working practices.
Only
technicians who have completed all required certification courses are permitted to
perform this procedure. Tesla recommends third party service provider technicians
undergo equivalent training before performing this procedure. For more information on
Tesla Technician requirements, or descriptions of the subject matter for third parties,
see HV Certification Requirements. Proper personal protective equipment (PPE) and insulating HV
gloves with a minimum rating of class 0 (1000V) must
be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness
Care Points
for additional safety
information.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Bolts (x3) that attach the fast charge contactor to the lower fast charge insulator |
![]() 5.5 Nm (4.1 lbs-ft) |
|
Reuse |
Remove
- Remove the HV battery fast charge negative DC link busbar. See Hose - Outlet - Power Conversion System (Remove and Replace).
- Remove the HV battery fast charge negative inlet busbar. See Busbar - Fast Charge - Input - Negative (Remove and Replace).
- Remove the HV battery fast charge positive DC link busbar. See Busbar - Fast Charge Contactor to DC Bus - Positive (Remove and Replace).
- Remove the HV battery fast charge positive inlet busbar. See Busbar - Fast Charge - Input - Positive (Remove and Replace).
-
Remove the bolts (x3) that attach the fast charge contactor to the lower
fast charge insulator, and then remove the contactor from the
insulator.
TIpUse of the following tool(s) is recommended:
- Socket External Torx 1/4in Dr. E8
Install
-
Install the HV battery fast
charge contactor to the lower fast charge insulator.
NoteAlign the 2 guides as the fast charge contactor is installed on the insulator.WarningThe video(s) included in this procedure are meant as an overview for supplemental purposes only. Follow all of the steps listed in the procedure to avoid damage to components and/or personal injury.
-
Install the bolts (x3) that
attach the fast charge contactor to the insulator, and then mark the bolts
with a paint pen after they are torqued.
5.5 Nm (4.1 lbs-ft)TIpUse of the following tool(s) is recommended:- Socket External Torx 1/4in Dr. E8
- Install the HV battery fast charge positive inlet busbar. See Busbar - Fast Charge - Input - Positive (Remove and Replace).
- Install the HV battery fast charge positive DC link busbar. See Busbar - Fast Charge Contactor to DC Bus - Positive (Remove and Replace).
- Install the HV battery fast charge negative inlet busbar. See Busbar - Fast Charge - Input - Negative (Remove and Replace).
- Install the HV battery fast charge negative DC link busbar. See Hose - Outlet - Power Conversion System (Remove and Replace).