Cooling System (Partial Refill and Bleed)
Correction code TBD 0.25 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
Procedure
- Remove the rear underhood apron. See Underhood Apron - Rear (Remove and Replace).
- Remove the coolant bottle cap.
-
Fill the coolant to the
proper level.
NoteEnsure that the coolant level is at the "Max" line.
- Unlock the vehicle gateway. See Gateway Unlock.
-
On the touchscreen, touch
Run to start
the "Coolant Air Purge" routine, and allow the routine to complete.
and select NoteMake sure vehicle is not in Drive, shifting the vehicle into Drive will stop this routine. The test will last approximately 10 mins. The test will vary speeds from 3500-6500 RPM (idle speed = ~1500 RPM) and actuate the valve between series and parallel. If speed hovers at 7000 RPM, it indicates the pump is air locked, perform the vacuum fill again. Continue to add coolant and purge until the coolant level reaches between the NOM and MAX Lines on the bottle.
-
Inspect the coolant level
and top off as necessary, and then install the coolant bottle cap.
NoteEnsure that the coolant level is at the "Max" line.
- Install the rear underhood apron. See Underhood Apron - Rear (Remove and Replace).