Cover - Left Terminals - Ancillary Bay (Remove and Replace)
Correction code 1630010222 FRT 0.90 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
- 1059330-00-B Skt, 1/4in Dr, 5-Lobe Torx Plus External
- 1108272-00-B CAP, LOGIC CONN, INV, 3DU
Only technicians who have been trained in High Voltage Awareness and have completed all required certification courses (if applicable) are permitted to perform this procedure. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points
for additional safety information.
Remove
-
Remove the ancillary bay cover.
See Ancillary Bay Cover (Remove and Replace).
WarningHV insulating gloves and leather glove protectors must be worn throughout the remainder of this procedure. Do not remove gloves or protectors until otherwise noted.
- Remove the pyrotechnic battery disconnect. See Pyro Disconnect - HV Battery (Remove and Replace).
-
Release the clip that attaches the ancillary bay harness around the negative
pack contactor.
WarningThe video(s) included in this procedure are meant as an overview for supplemental purposes only. Follow all of the steps listed in the procedure to avoid damage to components and/or personal injury.
- Release the tabs (x2) and datum that attach the LH ancillary bay terminal cover to the contactor busbar, and them remove the cover from the vehicle.
Install
- Fasten the tabs (x2) and datum that attach the LH ancillary bay terminal cover to the contactor busbar.
- Fasten the clip that attaches the ancillary bay harness around the negative pack contactor.
- Measure the voltage across the pyrotechnic battery disconnect mount points, and then install the pyrotechnic battery disconnect. See Pyro Disconnect - HV Battery (Remove and Replace).
-
Install the ancillary bay cover.
See Ancillary Bay Cover (Remove and Replace).
NoteBefore installing the ancillary bay cover, inspect the ancillary bay cover seal and confirm there is no visual damage. If the seal is torn and/or delaminated, replace the ancillary bay cover.