SOV Coil - Supermanifold (Remove and Replace)
Correction code 1840010112 FRT 0.24 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
Torque Specifications
Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
---|---|---|---|---|
Bolt that attaches the liquid cooled condenser shut off valve coil to the shut off valve core |
|
|
Reuse |
Remove
- Remove the underhood storage unit. See Underhood Storage Unit (Remove and Replace).
- Disconnect the LV battery power. See LV Battery - Li-lon (Disconnect and Connect).
-
Release the locking tab, and
then disconnect the electrical connector from the high pressure and
temperature sensor.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and
then disconnect the electrical connector from the recirc EXV (expansion
valve).
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and then disconnect the electrical connector from
the liquid cooled condenser EXV.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and then disconnect the electrical connector from
the liquid cooled condenser shut off valve.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and then disconnect the electrical connector from
the right side cabin condenser EXV.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and
then disconnect the electrical connector from the high pressure and
temperature subcool sensor.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and then disconnect the electrical connector from
the left side cabin condenser EXV.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and then disconnect the electrical connector from
the chiller EXV.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
-
Release the locking tab, and then disconnect the electrical connector from
the evap EXV.
CAUTIONDO NOT push down on the red locking tab. Pull the tab away from the connector until the connector is unlocked, and then continue pulling to release the connector.
- Move thermal harness from supermanifold to side.
-
Remove the bolt that
attaches the liquid cooled condenser shut off valve coil to the shut off
valve core, and then remove the liquid cooled condenser shut off valve coil
from the shut off valve core.
Tip: Use of the following tool(s) is recommended:
- 6 in extension
- Flex head ratchet/flex head torque wrench
- 3 mm hex
Install
-
Position the liquid cooled
condenser shut off valve coil on the shut off valve core.
NoteAlign the tab on the coil with the recess on the shut off valve core.
-
Install the bolt that
attaches the liquid cooled condenser shut off valve cooil to the shut off
valve core.Tip: Use of the following tool(s) is recommended:
- 6 in extension
- Flex head ratchet/flex head torque wrench
- 3 mm hex
- Route thermal harness back to supermanifold.
-
Connect the electrical connector on the evap EXV.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the chiller EXV.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the left side cabin condenser
EXV.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the right side cabin condenser
EXV.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the high pressure and temperature
subcool sensor.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the liquid cooled condenser shut off
valve.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the liquid cooled condenser EXV.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the recirc EXV.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
-
Connect the electrical connector on the high pressure and temperature
sensor.
CAUTIONPush the red locking tab towards the connector to engage the locking mechanism. DO NOT push down or pull up on the red locking tab.
- Connect LV power. See LV Battery - Li-lon (Disconnect and Connect).
- Install the underhood storage unit. See Underhood Storage Unit (Remove and Replace).