Actuator - HVAC (Remove and Replace)
Correction code
1810010072
FRT
2.58
NOTE: Unless
otherwise explicitly stated in the procedure, the above correction code and
FRT reflect all of the work required to perform this procedure, including
the linked procedures. Do
not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are
created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com.
NOTE: See Personal Protection to make
sure wearing proper PPE when performing the below procedure.
Torque Specifications
Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
---|---|---|---|---|
Bolts (x2) that attach the intake actuator to the HVAC assembly |
![]() 2.3 Nm (1.7 lbs-ft) |
|
Reuse |
Remove
- Remove the HVAC assembly. See HVAC Assembly (Remove and Replace).
- Disconnect the intake actuator connector.
-
Remove the bolts (x2) that attach the
intake actuator to the HVAC assembly.
TIpUse of the following tool(s) is recommended:
- 4 in extension
- Flex head ratchet/flex head torque wrench
- 6 mm socket
- Torx T20 bit
- Remove the intake actuator fixing bracket from the HVAC assembly.
- Remove the intake actuator from the HVAC assembly.
Install
-
Install the intake actuator to the
HVAC assembly.
NoteAlign the guide and push the actuator to secure during installation.
- Install the intake actuator fixing bracket to the HVAC assembly.
-
Install the bolts (x2) that attach the
intake actuator to the HVAC assembly.2.3 Nm (1.7 lbs-ft)TIpUse of the following tool(s) is recommended:
- 4 in extension
- Flex head ratchet/flex head torque wrench
- 6 mm socket
- Torx T20 bit
- Connect the intake actuator connector.