Vehicle Sanitation - Evaporator - Tunap 994 - (EMEA)
Correction code 18106728 0.36 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
- 1769621-00-A FOAMING CLEANER, TUNAP 994, AC EVEAPORATOR
Procedure
- Turn off A/C, set the cabin air to HI temperature, maximum blower speed and outside air intake, and then let the blower run for 8 minutes.
- Remove the combination filter. See Combination Filter - HVAC (Remove and Replace).
- Power off the vehicle through the touchscreen.
- Place a coolant drain container or absorbent material under the front of the vehicle.
- Pour 1 liter of Tunap 994 hygienic cleaner into the tank of the pressure cup spray gun, and then connect shop air to the spray gun.
-
Insert the probe in the HVAC
filter housing, and then spray all of the cleaning solution onto the
evaporator.
NoteThe spray holes in the probe should face to the rear of the vehicle, towards the evaporator.NoteBe sure to coat the entire evaporator with the cleaning solution.
-
Let the cleaning solution
sit on the evaporator for 30 minutes.
NoteWhile waiting, check under the vehicle and adjust the coolant drain container/absorbent material as necessary.
- Once the cleaning solution has sat long enough, install a new combination filter. See Combination Filter - HVAC (Remove and Replace).
- Turn on A/C, set the cabin air to LO temperature, maximum blower speed and outside air intake.
-
The cleaning foam will exit
through the HVAC drain. Continue to the next step once clean water is
observed exiting the HVAC drain.
- Remove the coolant drain container/absorbent material from under the vehicle.