Insulator - Fast Charge Access (Remove and Replace)
Correction code 1630010082 FRT 1.62 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Personal Protection to make sure wearing proper PPE when performing the below procedure.
Only technicians who have been trained in High Voltage Awareness and have completed all required certification courses (if applicable) are permitted to perform this procedure. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points
for additional safety information.
Remove
- Remove the fast charge contractor assembly. See Fast Charge Contactor (Remove and Replace).
- Remove and discard fast charge insulator cover from fast charge assembly.
Install
- Install the new fast charge insulator cover from fast charge assembly.
- Install the fast charge contractor assembly. See Fast Charge Contactor (Remove and Replace).