15/02/2024 08:32:50
Cover - Pyrotechnic Fuse - HV Battery 2.0 (Remove and Replace)
Correction code 16100602 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See to make sure wearing proper PPE when performing the below procedure.
Warning
Only technicians who have been
trained in High Voltage Awareness and have completed all required certification
courses (if applicable) are permitted to perform this procedure. Proper personal
protective equipment (PPE) and insulating HV gloves with a minimum rating of
class 0 (1000V) must be worn any time a high voltage cable is handled. Refer to
Tech Note TN-15-92-003, "High Voltage Awareness Care Points"
for additional safety information.
Warning
Proper personal
protective equipment (PPE) is required to perform this procedure:
- High voltage insulating gloves
- Leather glove protectors
- High voltage glove tester
- Safety glasses
- Electrical hazard rated safety shoes
Warning
If the vehicle has air
suspension, activate "Jack" mode on the touchscreen before raising and
supporting the vehicle.
Remove
- Move the vehicle to a 2 post lift. See Raise Vehicle - 2 Post Lift.
- Remove the HEPA filter housing. See Housing - Filter (Remove and Replace).
- Open the liftgate and rear doors.
-
Disconnect 12V power. See
Disconnect 12V Power.
NoteAllow at least 2 minutes before disconnecting high voltage components.
- Raise the vehicle to service under the HV battery.
- Remove all items from pockets and make sure not to wear any metal items.
-
Inspect the HV insulating
gloves.
NoteRefer to service document TN-15-92-003 for information on inspecting HV gloves.
- Put on the HV insulating gloves and the leather over gloves.
- Put on the HV-safe static control wrist strap. Clip the strap's ground connection to a threaded hole on the edge of the HV battery enclosure.
- Clean the area around the fuse cover with alcohol wipes.
- Remove the bolts (x6) that attach the fuse cover to the HV battery.
Install
- Use an IPA wipe to clean the sealing surface and gasket of the fuse cavity, the sealing surface of the fuse cover, and allow at least 1 minute to dry.
-
Install the fuse cover to
the HV battery, install the bolts (x6) that attach the fuse cover to the HV
battery, and then mark the bolts with a paint pen after
tightening.
- Remove the leather glove protectors and the HV insulating gloves.
- Connect 12V power. See Disconnect 12V Power.
- Install the HEPA filter housing. See Housing - Filter (Remove and Replace).
- Touch and hold the CALIBRATE button on the Model X touchscreen until the rear doors have been fully calibrated, close completely, and the message "CALIBRATION COMPLETE" is displayed.
- Remove the vehicle from the 2 post lift. See Raise Vehicle - 2 Post Lift.