2026-06-29

Fuse - Pyrotechnic - HV Battery 2.0 (Dismantle and Discard) (Modify)

Correction code 16308507 FRT 0.05 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and FRT listed above reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See Personal Protection to make sure you are wearing proper PPE when performing the procedure below. NOTE: See Ergonomic Precautions for safe and healthy working practices.

Informational PurposesAn informational icon, calling your attention
Note
Follow the steps below to dispose of a pyrotechnic battery fuse if local laws or regulations require disposal of separate materials

Procedure

  1. Remove the nut (7 mm) that attaches the pyrotechnic fuse cable to the contact plate.
  2. Release the connector from the pyrotechnic fuse assembly.
  3. Release the tabs (x2) to remove the insulator cover from the pyrotechnic fuse.
    Informational PurposesAn informational icon, calling your attention
    Note
    Push the front tab, and then pull the rear tab.
  4. Remove the nuts (x4, 7 mm) that attach the fuses to the pyrotechnic fuse assembly, and then remove the fuses.
  5. Separate the case from the pyrotechnic fuse.
  6. Loosen the nuts (x2, 13 mm) that attach the pyrotechnic module to the pyrotechnic fuse assembly.
  7. Release the tabs (x3) that secure the lower cover to the pyrotechnic fuse case, and then remove the lower cover.
  8. Loosen the screws (x3, T7) that attach the logic board to the pyrotechnic fuse case ,and then remove the logic board.
  9. Use a plastic trim tool to break the welds of the batteries, and then remove the batteries from the logic board.
  10. Sort all components and correctly dispose the separate components according to local regulations.