Light - Brake - High Mounted (Remove and Replace)
Correction Code 17402502
Removal
- Remove the liftgate glazing (refer to procedure) .
- Position the liftgate glazing on a suitable glazing stand.
- Note installed position of the Central High Mounted Stop Light (CHMSL).
-
Using a suitable tool to remove
the CHMSL from the liftgate glazing.
WarningTo avoid personal injury, eye protection must be worn when performing this operation.CAUTIONTake care not to damage component(s).
-
Remove the CHMSL.
Installation
-
Installation procedure is the reverse of removal, except for the following:
-
NoteClean the affected areas before installation.
- If the CHMSL is to be re-used, clean residual sealant from mating face.
- Clean any residual sealant from the glass.
- Spirit wipe and thoroughly clean glass that is next to the CHMSL.
- Make sure that the CHMSL is
correctly located.
- Print out the CHMSL template. Measure the "1 INCH" box to ensure the printout is properly scaled. See Chimsel Guide.
- Cut the templates along the dotted lines, and then attach the templates to the glass using masking tape.
- Remove the protective backings from the tape on the CHMSL.
- Install the CHMSL on the glass, ensuring the CHMSL aligns with the templates.
- Press onto the CHMSL to adhere it to the glass.
- Remove the templates from the glass.
- Tape the CHMSL harness to the glass.
- Wipe away any excess sealant
- Apply adhesive tape to keep the CHMSL in position and allow adhesive to cure.
-