23/05/2022 02:31:04
Instrument Cluster (Remove and Replace)
Correction Code 21050202
CAUTION
Before beginning this procedure, prepare a protected surface to set instrument cluster on when it is removed, such as placing a fender cover, towel, or other soft material onto a workbench.
CAUTION
The screen on the instrument cluster is very easy to scratch. When handling the instrument cluster, only touch the metal frame that surrounds the screen. Do not touch the screen, even when wearing gloves.
Removal
-
Perform an instrument cluster factory reset.
CAUTIONA factory reset of the instrument cluster is mandatory so that customer data is deleted prior to removal of the instrument cluster.
- Enable Service Mode. See Service Mode.
- Touch Controls > Service > Cluster Factory Reset.
- Move the steering wheel fully downwards and away from the instrument panel.
- Remove the driver's outboard face level vent (refer to procedure).
- Remove driver's inboard face level vent (refer to procedure).
- Disconnect 12V power. See Disconnect 12V Power .
-
Remove the screws (x4) that secure the instrument cluster to the IP carrier (torque 2 Nm).
-
Carefully release the instrument cluster from the IP carrier to access the harness connections.
CAUTIONDo not touch the screen.
-
Disconnect the electrical connectors (x2) from the rear of the instrument cluster.
CAUTIONProtect the harnesses connectors from contamination and dirt ingress.
-
Carefully remove the instrument cluster and put it onto a protected surface.
CAUTIONDo not touch the screen.
Installation
Installation procedure is the reverse of removal, except for the following:
Reinstall the latest
vehicle firmware, or update the firmware if not the latest. See Firmware Reinstall - Touchscreen or Firmware Update.
Note
To reduce overlap time,
reconnect 12V power, start the update process, and reinstall all components during
the update process.