1620 – Système de refroidissement de batterie haute tension Liens connexes Tube - sortie - liquide de refroidissement - système de conversion d’énergie (Ensemble structural) (retirez et remplacez) Code de correction 16202302 3.12 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Tuyau - entrée - liquide de refroidissement - système de conversion d’énergie (Ensemble structural) (retirez et remplacez) Code de correction 16202402 3.12 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Liquide de refroidissement des baies auxiliaires (vidange et remplissage) Code de correction 16202000 1.90 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Test d'étanchéité du liquide de refroidissement des baies auxiliaires Code de correction 16200200 1.80 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Liquide de refroidissement du boîtier du plateau (vidange et remplissage) Code de correction 16102020 0,85 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Test de fuite de liquide de refroidissement du boîtier du plateau Code de correction 16102010 1.15 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Tuyau - entrée - liquide de refroidissement - système de conversion d’énergie (retirez et remplacez) Code de correction 16202002 3.24 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Tube - sortie - liquide de refroidissement - système de conversion d’énergie (retirez et remplacez) Code de correction 16202202 2.52 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Sujet parent : 16 – Système de batterie