2024-08-28

Connecteur du système de diagnostic embarqué (modification)

Code de correction 00050300 0,24 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure.

  • Outils requis :
    • 1115191-00-A – Petit pic à prise souple, embout à 90 degrés, 6 po
    • 1706381-00-A – Pistolet thermique sans fil
    • 1061177-00-C – TROUSSE, RÉPARATION DU FAISCEAU DE CÂBLES
    • 1944989-00-A – Outil de démontage 45 degrés

Remaniement

  1. Débranchez la batterie BT et la boucle de premier intervenant. Voir Alimentation 12 V/BT (déconnectez et connectez).
  2. Retirez le recouvrement de l'espace de jambes gauche. Voir Couvercle - espace pour les jambes - conducteur (retirez et remplacez).
  3. Retirez la borne de fil de la broche 3 (violet) du connecteur du système de diagnostic embarqué.
  4. Retirez la borne de fil de la broche 11 (blanche) du connecteur du système de diagnostic embarqué.
  5. Installez le tube thermorétractable sur les bornes de fil des broches 3 et 11.
  6. Appliquez du ruban adhésif pour fixer les bornes de fil retravaillées des broches 3 et 11 sur l'ensemble du faisceau de câbles du connecteur du système de diagnostic embarqué.
  7. Installez le recouvrement de l’espace de jambes gauche. Voir Couvercle - espace pour les jambes - conducteur (retirez et remplacez).
  8. Branchez la batterie BT et la boucle de premier intervenant. Voir Alimentation 12 V/BT (déconnectez et connectez).