08/04/2024 19:52:27

Event Data Recorder Retrieval

교정 코드 NA

Warning IconA warning icon, calling your attention to a possibly risky situation
경고
이 절차는 검증되었지만 초안입니다. 경고와 주의사항이 누락되었을 수 있습니다. 고전압 시스템 및 구성 요소에서 또는 그 근처에서 작업하는 경우에는 안전 요구 사항을 준수하고 최고 수준의 주의를 기울여야 합니다. 수정 사항 및 기타 의견이 있으면 ServiceDevelopment@teslamotors.com으로 알려 주십시오.
Informational PurposesAn informational icon, calling your attention
참고
Refer to CD-20-20-001 for Model Y Event Data Recorder (EDR) guide.
Informational PurposesAn informational icon, calling your attention
참고
Use the following procedure(s) for Model Y Non-Structural Pack EDR retrieval as required:
Informational PurposesAn informational icon, calling your attention
참고
Use the following procedure(s) for Model Y Structural Pack EDR retrieval as required:

Establish a Direct-to-Module Connection (Non-Structural Pack)

  1. Open all of the doors.
  2. Lower all of the windows.
  3. On the vehicle touchscreen, select the Tesla symbol, and then confirm and note the vehicle’s firmware version.
    그림 1. Model 3 shown; Model Y similar
  4. Remove the Restraint Control Module (RCM). See 모듈 - 구속 장치 제어(구조용 팩 이외) (탈거 및 교체).
  5. Connect the EDR extraction harness connectors (x2) to the RCM.
    Informational PurposesAn informational icon, calling your attention
    참고
    다음 공구 사용을 권장합니다.
    • EDR extraction harness, RCM, Bosch MS-M3-MY - 1492139-00-B
  6. Connect the EDR extraction harness connector to the PCAN USB to CAN adapter connector.
    Informational PurposesAn informational icon, calling your attention
    참고
    다음 공구 사용을 권장합니다.
    • PCAN USB to CAN adapter - 1016990-00-A
  7. Connect the PCAN USB to CAN adapter dongle connector to the laptop USB port.
  8. Connect the XP-20 (heavy duty) jump start 12V power to the EDR extraction harness.
    Informational PurposesAn informational icon, calling your attention
    참고
    Jump start, XP-20 (heavy duty) - 1016990-00-A
  9. Open the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    참고
    The program will automatically try to connect to RCM and will display a green circle in the lower left corner when connected.
  10. Once the Tesla EDR Retrieval Program connection is established, click "Run EDR Retrieval", and then follow the on-screen prompts to retrieve and save the EDR data.
  11. Use the retrieved data to "Generate a Report". See https://edr.tesla.com.
    Informational PurposesAn informational icon, calling your attention
    참고
    EDR retrieval time will vary based on the user and retrieved data.
  12. Close the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    참고
    Select "X" at the top right of the window to close the program once EDR retrieval is complete.
  13. Disconnect the XP-20 (heavy duty) jump start 12V power from the EDR extraction harness.
  14. Disconnect the PCAN USB to CAN adapter dongle connector from the laptop USB port.
  15. Disconnect the EDR extraction harness connector from the PCAN USB to CAN adapter connector.
  16. Disconnect the EDR extraction harness connectors (x2) from the RCM.
  17. Install the RCM. See 모듈 - 구속 장치 제어(구조용 팩 이외) (탈거 및 교체).
  18. Raise all of the windows.
  19. Close all of the doors.

Establish a Direct-to-Module Connection (Structural Pack)

  1. Remove the RCM. See 모듈 - 구속 제어(구조용 팩)(탈거 및 교체).
  2. Connect the EDR extraction harness connectors (x2) to the RCM.
    Informational PurposesAn informational icon, calling your attention
    참고
    다음 공구 사용을 권장합니다.
    • EDR extraction harness, RCM, Bosch MS-M3-MY - 1492139-00-B
  3. Connect the EDR extraction harness connector to the PCAN USB to CAN adapter connector.
    Informational PurposesAn informational icon, calling your attention
    참고
    다음 공구 사용을 권장합니다.
    • PCAN USB to CAN adapter - 1016990-00-A
  4. Connect the PCAN USB to CAN adapter dongle connector to the laptop USB port.
  5. Connect the XP-20 (heavy duty) jump start 12V power to the EDR extraction harness.
    Informational PurposesAn informational icon, calling your attention
    참고
    Jump start, XP-20 (heavy duty) - 1016990-00-A
  6. Open the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    참고
    The program will automatically try to connect to RCM and will display a green circle in the lower left corner when connected.
  7. Once the Tesla EDR Retrieval Program connection is established, click "Run EDR Retrieval", and then follow the on-screen prompts to retrieve and save the EDR data.
  8. Use the retrieved data to "Generate a Report". See https://edr.tesla.com.
    Informational PurposesAn informational icon, calling your attention
    참고
    EDR retrieval time will vary based on the user and retrieved data.
  9. Close the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    참고
    Select "X" at the top right of the window to close the program once EDR retrieval is complete.
  10. Disconnect the XP-20 (heavy duty) jump start 12V power from the EDR extraction harness.
  11. Disconnect the PCAN USB to CAN adapter dongle connector from the laptop USB port.
  12. Disconnect the EDR extraction harness connector from the PCAN USB to CAN adapter connector.
  13. Disconnect the EDR extraction harness connectors (x2) from the RCM.
  14. Install the RCM. See 모듈 - 구속 제어(구조용 팩)(탈거 및 교체).