1701 – Batterie 12 V et fusibles Liens connexes 12V/LV Power (Disconnect and Connect) 12V/LV Battery (Remove and Replace) Beam - 12V Battery (Dual Motor) (Remove and Replace) Code de correction 17012712 1.56 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Beam - 12V Battery (RWD) (Remove and Replace) Code de correction 17012702 0.72 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Bracket - 12V Battery (Dual Motor) (Remove and Replace) Code de correction 170140121.56 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Bracket - 12V Battery (RWD) (Remove and Replace) Code de correction 17014002 0.48 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. LV Maintainer (Connect and Disconnect) Code de correction 17010500 0.05 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Strap - 12V Battery (Remove and Replace) Code de correction 17014202 0.12 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Vehicle HV Disablement Procedure Code de correction 17010000 0.24 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Vent Hose - 12V Battery (Remove and Replace) Code de correction 17011002 0.12 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure. Sujet parent : 17 – Système électrique