Ensemble d’entrée CC - batterie HT (type faisceau) (retirez et remplacez)
Code de correction 16302302 1.38 NOTE: Unless otherwise explicitly stated in the procedure, the above correction code and FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.NOTE: See Flat Rate Times to learn more about FRTs and how they are created. To provide feedback on FRT values, email LaborTimeFeedback@tesla.com. NOTE: See Protection individuelle to make sure wearing proper PPE when performing the below procedure.
- 1057602-00-A Clé à rochet, carré cond. 1/4 po, isolé haute tension
- 1057606-00-A Douille, carré cond. 1/4 po, 13 mm, isolé haute tension
- 1057607-00-A Aimant, flexible, isolé haute tension, 18 po
- 1059330-00-B Douille, cond. 1/4 po, embout Torx externe Plus 5-Lobe
- 1076927-00-A Resistance meter, microohm, Hioki RM 3548
Only
technicians who have been trained in High Voltage Awareness and
have completed all required certification courses (if applicable) are permitted to
perform this procedure. Proper personal protective equipment
(PPE) and insulating HV gloves with a minimum rating
of class 0 (1000V) must be worn at all times a high voltage
cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness
Care Points
for additional safety
information.
Retirer
- Retirez le sectionneur de batterie pyrotechnique. Voir Sectionneur de batterie pyrotechnique (retirez et remplacez).
- Remove the insulator for the DC input assembly.
- Remove and discard the bolts that attach the DC input busbars to the fast charge contactor busbars.
- Disconnect the electrical harness from the DC input assembly connector.
- Remove the bolts that attach the DC input assembly to the ancillary bay, and then remove the DC input assembly from the vehicle.
Installer
- Perform a zero adjust of the Hioki resistance meter in preparation to measure resistances later in this procedure. See Compteur de résistance (réglage zéro).
-
Install the DC input assembly to the ancillary bay, install the bolts (x4) that attach the DC input assembly to the ancillary bay, and then mark the bolts with a paint pen after they are torqued..6 Nm (4.4 lbs-ft)
- Install new bolts (x2) to attach the DC input busbars to the fast charge contactor busbars.
-
Precondition the bolts by
torquing to 15 Nm, then back off one half turn, retorque to 5 Nm +60 deg,
and then mark the bolts with a paint pen.15 Nm (11.1 lbs-ft) -180 deg5 Nm (3.7 lbs-ft) +60 deg
-
Use the Hioki resistance meter to measure the resistance at the HV joint between the positive DC input busbar and the positive (LH) fast charge contactor busbar.
NoteThe maximum acceptable resistance is 0.060 mΩ (60 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
-
Use the Hioki resistance meter to measure the resistance at the HV joint between the negative DC input busbar and the negative (RH) fast charge contactor busbar.
NoteThe maximum acceptable resistance is 0.060 mΩ (60 μΩ). There is too much resistance in the High Voltage joint. Remove the fastener, clean areas with isopropyl alcohol, install fastener back and test again
- Install the insulator for the DC input assembly.
- Connect the electrical harness to the DC input assembly connector.
- Mesurez la tension à travers les points de montage de déconnexion de la batterie pyrotechnique puis installez la déconnexion de la batterie pyrotechnique Voir Sectionneur de batterie pyrotechnique (retirez et remplacez).
-
Install the ancillary bay cover. See Couvercle - baie auxiliaire (retirer et remplacer).
NotePerform an ancillary bay air leak test when instructed to do so.
- Connect 12V power. See Alimentation 12 V/BT (déconnectez et connectez).