Fill Valve - Air (Retrofit)
Code de correction 31103206
Avertissement
Cette procédure est un BROUILLON, même si elle a été validée. Il peut manquer des avertissements et des mises en garde. Respectez les exigences de sécurité et faites preuve d’une extrême prudence lorsque vous travaillez sur ou près de systèmes et de composants haute tension. Transmettez toute correction ou remarque à ServiceDevelopment@teslamotors.com.
- Open LH front door
-
Open hood
RemarqueVia center display > Controls > Front Trunk
- Connect a laptop with Toolbox 3 to the vehicle.
- For Tesla air suspensions, in Toolbox 3, click the Actions tab, type "Service-Mode" into the search field, click PROC_TAS_X_ENTER-SERVICE-MODEvia Toolbox: (link), click Run, and allow the routine to complete.
- To deflate the reservoir, in Toolbox 3, click the Actions tab, type "Deflate" into the search field, click PROC_TAS_X_DEFLATEvia Toolbox: (link)via Service Mode: Chassis ➜ Suspension ➜ Deflate, click Run, and allow the routine to complete.
-
Remove rear underhood apron
Remarque11x clips
-
Remove cable tie securing air lines to RH shock tower
Remarque1x cable tie
-
Cut black air suspension line between compressor and reservoir at RH shock tower
RemarqueWarning: High pressure air line, Failure to deflate system could lead to personal injury, Be sure to wear proper PPE
-
Remove plugs from fill valve
-
Install fill valve onto black air suspension line between compressor and reservoir
RemarqueFully push air line into fitting and give a slight pull to confirm line is fully engaged
-
Secure fill valve and air lines to clip at RH shock tower
Remarque2x cable ties, Secure properly to prevent NVH
-
Remove cap from fill valve
-
Verify red pressure regulator valve is fully closed
-
Open main valve on nitrogen tank
RemarqueVerify pressure is between 500-1500psi
-
Verify valve at hose adapter is closed
-
Attach nitrogen tank adapter to the inline fill valve
-
Open the pressure regulator valve on the nitrogen tank to release the line pressure in the lines
RemarqueOpen regulator valve to adjust pressure to 19-21 bar (275-305 psi), Open the valve slowly as gas pressure rises
-
Open lever on hose adapter to fill reservoir
RemarqueSupplying Nitrogen automatically fills the reservoir. Nitrogen supply begins filling the reservoir up to 290 psi or 20 bar. Give it some time to settle pressure equally between set Nitrogen set pressure and vehicle reservoir.
- In Toolbox 3, click the Actions tab, type "Normal-Mode" into the search field, click PROC_TAS_X_ENTER-NORMAL-MODEvia Toolbox: (link), click Run, and allow the routine to complete.
-
Set vehicle ride height to Very Low
RemarqueVia center display > Controls > Suspension > Very Low, Perform during nitrogen fill to purge water out of air suspension system and fully charge reservoir
-
Set vehicle ride height to Very High
RemarqueVia center display > Controls > Suspension > Very High, Perform during nitrogen fill to purge water out of air suspension system and fully charge reservoir
-
Set vehicle ride height to Standard
RemarqueVia center display > Controls > Suspension > Standard, Perform during nitrogen fill to purge water out of air suspension system and fully charge reservoir
-
Close lever on hose adapter to fill reservoir
-
Close main valve on the nitrogen tank
-
Close the pressure regulator valve on the nitrogen tank
-
Disconnect the nitrogen tank adapter from the inline fill valve
-
Install cap onto fill valve
-
Install rear underhood apron
Remarque11x clips
- Close hood
-
Disconnect laptop from vehicle and install storage cubby
Remarque1x connect, 2x clips, Ensure diagnostic cables are tucked into the appropriate position
- Close LH front door