Drive Motor Assembly - Roadster 2.x
Correction code 40012302
Remove
- Remove motor from transmission (refer to procedure).
- Position motor on work bench.
-
Remove screws (x5) securing cable cover to motor (torque 2 Nm).
NoteWhen installing, apply Loctite®222™ thread locking compound to bolt/screw threads.
- Remove cable cover.
-
Remove Nomex insulator.
-
Remove brass bolts (x3), copper washers and serrated Belleville washers (torque 17 Nm).
NoteThe serrated Belleville washers must be fitted with the raised inner diameter against the bolt head.
- Remove screws (x2) securing cable shield to motor.
- Release cable shield and grommet from motor and remove motor cable.
- Remove grommet from motor cable.
-
Remove motor lifting clamp 1001030 (Motor Lifting Clamp).
Install
Installation procedure is the reverse of removal, except for the following:
- Apply a light coating of Kopr-Shield™ Compound to face of motor terminals.
- Clean and inspect Nomex insulator for damage and replace if necessary.
- Make sure that cable grommet is correctly installed on cable and motor.