10/02/2017 09:09:31
Pipe - Low Pressure - Charge Port
Correction code 18032202
Remove
- Recover the A/C refrigerant (refer to procedure).
- Remove HVAC controller (refer to procedure).
-
Loosen union and remove the low pressure charge port pipe (torque 15 Nm).
CAUTIONTo prevent damage always use a suitable wrench to hold backing nut when loosening pipes and unions.CAUTIONPlug pipe connections to prevent ingress of moisture or dirt.
- Remove P-clip from pipe.
Install
Installation procedure is the reverse of removal, except for the following:
- Replace A/C pipe O-ring.